We install Liquid Storage systems for our customers where the consumption of gases are substantially higher for the investments customers make for the system. We can install the system for the consumption of gases like – CO2, Argon, Nitrogen, Oxygen. The system consists of the following:
- Tanks – Vacuum Insulated/PUF Insulated. PUF insulated is used only for CO2 applications. Capacity of the tank can vary w.r.t to the consumption of the user.
- Vaporizers – This is used to convert the liquid in the tank to gaseous state for final consumption. Capacity of the vaporizer can vary w.r.t to the consumption of the user.
- Pressure Reducing Station (PRS) – Generally the liquid state of the gas is stored at a pressure in which it is manufactured. The user may require the gas consumption at a much lesser pressure. This system is used to reduce the pressure of the gas to the desired level at the consumption point. This is achieved by using pressure regulators.
- Refrigeration Unit : This unit is installed for LCO2 storage (PUF tanks) system and is used to control the pressure build up in the tanks. This ensures that the operational pressure is maintained all the time.
- Load cell/DP Transmitter with Telemetry – This is installed for all tanks to show the actual stock of the liquid present in the tanks. A telemetry unit is installed to access the critical parameters like – Stock, Pressure, temperature of the tank real time in a cloud system and can alert the user w.r.t any deviation in parameters. This system also enables suppliers to plan the next supply without the involvement or instructions from the user.